custom-intranet/utils/p4runtime_switch.py
2026-11-08 16:49:31 -07:00

139 lines
4.9 KiB
Python

# SPDX-FileCopyrightText: 2017 Barefoot Networks, Inc.
# SPDX-FileCopyrightText: 2017 Open Networking Foundation
#
# SPDX-License-Identifier: Apache-2.0
import os
import tempfile
from time import sleep
from mininet.log import debug, error, info
from mininet.moduledeps import pathCheck
from mininet.node import Switch
from netstat import check_listening_on_port
from p4_mininet import SWITCH_START_TIMEOUT, P4Switch
class P4RuntimeSwitch(P4Switch):
"BMv2 switch with gRPC support"
next_grpc_port = 50051
next_thrift_port = 9090
def __init__(self, name, sw_path = None, json_path = None,
grpc_port = None,
thrift_port = None,
pcap_dump = False,
log_console = False,
verbose = False,
device_id = None,
enable_debugger = False,
log_file = None,
**kwargs):
Switch.__init__(self, name, **kwargs)
assert (sw_path)
self.sw_path = sw_path
# make sure that the provided sw_path is valid
pathCheck(sw_path)
if json_path is not None:
# make sure that the provided JSON file exists
if not os.path.isfile(json_path):
error("Invalid JSON file: {}\n".format(json_path))
exit(1)
self.json_path = json_path
else:
self.json_path = None
if grpc_port is not None:
self.grpc_port = grpc_port
else:
self.grpc_port = P4RuntimeSwitch.next_grpc_port
P4RuntimeSwitch.next_grpc_port += 1
if thrift_port is not None:
self.thrift_port = thrift_port
else:
self.thrift_port = P4RuntimeSwitch.next_thrift_port
P4RuntimeSwitch.next_thrift_port += 1
if check_listening_on_port(self.grpc_port):
error('%s cannot bind port %d because it is bound by another process\n' % (self.name, self.grpc_port))
exit(1)
self.verbose = verbose
logfile = "/tmp/p4s.{}.log".format(self.name)
self.output = open(logfile, 'w')
self.pcap_dump = pcap_dump
self.enable_debugger = enable_debugger
self.log_console = log_console
if log_file is not None:
self.log_file = log_file
else:
self.log_file = "/tmp/p4s.{}.log".format(self.name)
if device_id is not None:
self.device_id = device_id
P4Switch.device_id = max(P4Switch.device_id, device_id)
else:
self.device_id = P4Switch.device_id
P4Switch.device_id += 1
self.nanomsg = "ipc:///tmp/bm-{}-log.ipc".format(self.device_id)
self.cpu_port = None
if "cpu_port" in kwargs:
self.cpu_port = kwargs["cpu_port"]
self.priority_queues = None
if "priority_queues" in kwargs:
self.priority_queues = kwargs["priority_queues"]
def check_switch_started(self, pid):
for _ in range(SWITCH_START_TIMEOUT * 2):
if not os.path.exists(os.path.join("/proc", str(pid))):
return False
if check_listening_on_port(self.grpc_port):
return True
sleep(0.5)
def start(self, controllers):
info("Starting P4 switch {}.\n".format(self.name))
args = [self.sw_path]
for port, intf in list(self.intfs.items()):
if not intf.IP():
args.extend(['-i', str(port) + "@" + intf.name])
if self.pcap_dump:
args.append("--pcap %s" % self.pcap_dump)
if self.nanomsg:
args.extend(['--nanolog', self.nanomsg])
args.extend(['--device-id', str(self.device_id)])
P4Switch.device_id += 1
if self.json_path:
args.append(self.json_path)
else:
args.append("--no-p4")
if self.enable_debugger:
args.append("--debugger")
if self.log_console:
args.append("--log-console")
if self.thrift_port:
args.append('--thrift-port ' + str(self.thrift_port))
if self.grpc_port:
args.append("-- --grpc-server-addr 0.0.0.0:" + str(self.grpc_port))
if self.cpu_port:
args.append("--cpu-port " + str(self.cpu_port))
if self.priority_queues:
args.append("--priority-queues " + str(self.priority_queues))
cmd = ' '.join(args)
info(cmd + "\n")
print(cmd + "\n")
pid = None
with tempfile.NamedTemporaryFile() as f:
self.cmd(cmd + ' >' + self.log_file + ' 2>&1 & echo $! >> ' + f.name)
pid = int(f.read())
debug("P4 switch {} PID is {}.\n".format(self.name, pid))
if not self.check_switch_started(pid):
error("P4 switch {} did not start correctly.\n".format(self.name))
exit(1)
info("P4 switch {} has been started.\n".format(self.name))